Home Categories Send inquiry

LT – WY02 Constant temperature water nozzle comprehensive performance testing machine

Technical Parameters

The serial number

According to project name

Want to ask

1

Work pressure

0.1 ~ 1.0 MPa

2

Hydraulic resolution

0.001 MPa

3

Temperature range

0 ~ 100.0 ℃

4

The temperature precision

±1℃, can be displayed to 0.1℃

5

Pressure sensor range

0 ~ 1.0 MPa

6

Pressure sensor accuracy

0.5% accuracy

7

Flow sensor range

2 ~ 30 LPM

8

Flow sensor accuracy

1% accuracy

9

Temperature sensor range of outlet

0 ~ 100 ℃

10

Accuracy of outlet temperature sensor

Plus or minus 0.5 ℃

11

Time range

1 second ~ 600 minutes adjustable

12

Time precision

Plus or minus 0.02 seconds

Comply with standards and clauses

Product class

Standard said

Article standards

Temperature control water mouth

QB 2806-2017

8.7.2 sealing performance

Temperature control water mouth

QB 2806-2017

8.7.4 stability of outlet water temperature

Temperature control water mouth

QB 2806-2017

8.7.5 security

Temperature control water mouth

QB 2806-2017

8.7.6 maximum outlet water temperature

Nc constant temperature nozzle

GB/T 24293-2009

7.4.7 stability of outlet water temperature

Nc constant temperature nozzle

GB/T 24293-2009

7.4.8 outlet water temperature, output water test and maximum outlet water temperature at loss of cold water supply

Nc constant temperature nozzle

GB/T 24293-2009

7.4.9 initial temperature setting

Nc constant temperature nozzle

GB/T 24293-2009

7.4.10 energy consumption test of the whole machine

Inductive temperature-controlled nozzle

QB/T 4000-2010

7.9.8 stability of outlet water temperature

Inductive temperature-controlled nozzle

QB/T 4000-2010

7.9.9 security testing

Automatic Compensating Valves

ASSE1016-2011.

4.2.2 High - temperature conditioning

Automatic Compensating Valves

ASSE1016-2011.

4.3 Working pressure test

Automatic Compensating Valves

ASSE1016-2011.

4.4 Maximum operating torque or force adjustment test

Automatic Compensating Valves

ASSE1016-2011.

4.6 Pressure and temperature variation test

Automatic Compensating Valves

ASSE1016-2011.

4.7 Water supply failure test

Automatic Compensating Valves

ASSE1016-2011.

4.8 Mechanical temperature limit stop test

Automatic Compensating Valves

ASSE1016-2011.

4.9 Outlet temperature and flow capacity test


LT – WY02 Constant temperature water nozzle comprehensive performance testing machine Related Video: